PF PUFFER

PF/PFS Puffer comes with 8 connections for use in heating systems. PF/PFS hydraulic separators prevent interference between primary (heat source) and secondary circuit (head delivery). Puffer is made from primary coated carbon steel.

From 300 to 500 liters:
30 mm non-removable closed-cells rigid PUR insulation + PVC outer jacket.

From 800 to 2000 liters:
Soft polyester removable insulation + PVC outer jacket.

GENERAL TECHNICAL DATA

Specifications

  • Maximum operating temperature: +95 °C
  • Maximum Operating Pressure: 4 bar
  • Fluids: water – water/glycol mixtures (max 30%)

Materials

  • Puffer body: S235jr
  • Insulation: PUR 30 mm + PVC, Dens. 40 kg/m3, Cond. 0.025 W/mK
  • Insulation: 100 mm polyester + PVC, Dens. 18 kg/m3 Cond. 0.04 W/mK

REF. PF

300 L

500 L

800 L

1000 L

1500 L

2000 L

h (mm)

1595

1645

1750

2110

2115

2380

O.D.

600

750

1050

1050

1260

1360

A

215

240

275

275

340

370

B (solo per PFS)

290

315

355

350

420

450

C

595

615

655

810

765

930

D (solo per PFS)

810

835

875

1035

1080

1090

E

1080

1105

1145

1355

1400

1435

F

1350

1375

1410

1755

1725

1945

Net capacity (lt)

389.8 499.8

749.3

931.0

1472.4

1950.0

Heat dispersion (W)

57.3

69.7

129.4

141.2

168.2

184.0

Heat ex. (m2) / (lt)

1.4 / 13.7

2.0 / 19.6

2.5 / 24.5

3.5 / 34.3

4.0 / 39.2

4.8 / 47.0

Packaging L x B x H (mm)

800 x 800 x 1775 800 x 800 x 1775

1200 x 1200 x 1880

1200 x 1200 x 2240

1400 x 1400 x 2215

1400 x 1400 x 2480

Packaging weight (kg)

80 120

159

193

247

311

REF

DESCRIPTION

300 L

500 L

800 L

1000 L

1500 L

2000 L

1

Biomass outlet

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
2

Biomass return

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
3

System outlet

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
4

System return

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
5

Service connection

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
6

Heating system return

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
7

Elect. resist. provision

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
8

Sensor probe provision

1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
9

Heating system supply

1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2 1” 1/2
10

Heat exchanger inlet (PFS)

1” 1” 1” 1” 1” 1”
11

Heat exchanger outlet (PFS)

1” 1” 1” 1” 1” 1”

REF. PF

300 L

500 L

800 L

h (mm)

1595

1645

1750

O.D.

600

750

1050

A

215

240

275

B (solo per PFS)

290

315

355

C

595

615

655

D (solo per PFS)

810

835

875

E

1080

1105

1145

F

1350

1375

1410

Net capacity (lt)

389.8 499.8

749.3

Heat dispersion (W)

57.3

69.7

129.4

Heat ex. (m2) / (lt)

1.4 / 13.7

2.0 / 19.6

2.5 / 24.5

Packaging L x B x H (mm)

800 x 800 x 1775 800 x 800 x 1775

1200 x 1200 x 1880

Packaging weight (kg)

80 120

159

REF. PF

1000 L

1500 L

2000 L

h (mm)

2110

2115

2380

O.D.

1050

1260

1360

A

275

340

370

B (solo per PFS)

350

420

450

C

810

765

930

D (solo per PFS)

1035

1080

1090

E

1355

1400

1435

F

1755

1725

1945

Net capacity (lt)

931.0

1472.4

1950.0

Heat dispersion (W)

141.2

168.2

184.0

Heat ex. (m2) / (lt)

3.5 / 34.3

4.0 / 39.2

4.8 / 47.0

Packaging L x B x H (mm)

1200 x 1200 x 2240

1400 x 1400 x 2215

1400 x 1400 x 2480

Packaging weight (kg)

193

247

311

REF

DESCRIPTION

300 L

500 L

800 L

1

Biomass outlet

1” 1/2 1” 1/2 1” 1/2
2

Biomass return

1” 1/2 1” 1/2 1” 1/2
3

System outlet

1” 1/2 1” 1/2 1” 1/2
4

System return

1” 1/2 1” 1/2 1” 1/2
5

Service connection

1” 1/2 1” 1/2 1” 1/2
6

Heating system return

1” 1/2 1” 1/2 1” 1/2
7

Elect. resist. provision

1” 1/2 1” 1/2 1” 1/2
8

Sensor probe provision

1/2” 1/2” 1/2”
9

Heating system supply

1” 1/2 1” 1/2 1” 1/2
10

Heat exchanger inlet (PFS)

1” 1” 1”
11

Heat exchanger outlet (PFS)

1” 1” 1”

REF

DESCRIPTION

1000 L

1500 L

2000 L

1

Biomass outlet

1” 1/2 1” 1/2 1” 1/2
2

Biomass return

1” 1/2 1” 1/2 1” 1/2
3

System outlet

1” 1/2 1” 1/2 1” 1/2
4

System return

1” 1/2 1” 1/2 1” 1/2
5

Service connection

1” 1/2 1” 1/2 1” 1/2
6

Heating system return

1” 1/2 1” 1/2 1” 1/2
7

Elect. resist. provision

1” 1/2 1” 1/2 1” 1/2
8

Sensor probe provision

1/2” 1/2” 1/2”
9

Heating system supply

1” 1/2 1” 1/2 1” 1/2
10

Heat exchanger inlet (PFS)

1” 1” 1”
11

Heat exchanger outlet (PFS)

1” 1” 1”

PRODUCT LIST

DESCRIPTION

CODE

Energ. cl.

PF PUFFER – 300

343000 B

PF PUFFER – 500

343001 B

PF PUFFER – 800

343002

PF PUFFER – 1000

343003

PF PUFFER – 1500

343004

PF PUFFER – 2000

343005

Listino accessori

REF.

DESCRIPTION

CODE

1

THERMOMETER 0 / + 120 °C – 10 cm (1 PC)

904001

THERMOMETER -30 / + 50 °C – 10 cm (1 PC)

904003

THERMOMETER 0 / + 60 °C – 10 cm (1 PC)

904005

2

 

CASING FOR 6.5 mm X 10 cm COPPER PROBE (1 PC)

904053

CASING FOR 9.5 mm x 10 cm COPPER PROBE (1 PC)

904051

3

 

 

 

 

HEATING ELEMENT WITH THERMOSTAT 230V – 3 kW (1 PC)

903110

HEATING ELEMENT WITH THERMOSTAT 400V – 4 kW (1 PC)

903111

HEATING ELEMENT WITH THERMOSTAT 400V – 5 kW (1 PC)

903112

HEATING ELEMENT WITH THERMOSTAT 400V – 7.5 kW (1 PC)

903113

HEATING ELEMENT WITH THERMOSTAT 400V – 9 kW (1 PC)

903114

Related products

Double coil base inertial storage tank

18 April 2025

Single coil base inertial storage tank

18 April 2025

Inertial accumulator and base separator, 8 connections

18 April 2025

Inertial accumulator and base separator, 4 connections

18 April 2025

Inertial accumulation and suspended separator

18 April 2025