Wall-mounted instantaneous DHW heater
FW module are designed for instantaneous DHW production. Installation with a thermal storage is ideal solution in small to medium-sized applications. FW modules can be installed individually or in cascade up to 8 modules. They ensure from 2 to 320 L/min DHW capacity.
FW modules are ideal in reduced room for installation conditions. They drastically reduce maintenance expenses, and improve home safety by reducing hazard from Legionella in DHW systems.
FW modules facilitate energy efficient installations by storing heated water at higher temperature than DHW.
FW40 / FW40 PLUS: The temperature regulation is set out through a control unit combined with a flow sensor.
The product is factory set for installations in cascade systems.
- DATI TECNICI GENERALI
- DIMENSIONAL
- PRODUCTS/ACCESSORIES LISTING
- VALVE KIT
- TECHNIC DATA
- FUNCTIONAL SCHEME
- INSTALLATION SCHEME
- PERFORMANCE CURVE
GENERAL TECHNICAL DATA
Specifications
- Maximum operating temperature: 85 °C
- Maximum operating pressure for the system: 3 bar
- Maximum operating pressure for DHW: 6 bar
- Connections: IN/OUT 1″ Male SP
- Fluids: water – water/glycol mixtures (max 30%)
Materials
- Heat Exchanger: AISI 316
- Pipelines: Copper
- Hydraulic seals: EPDM
- Fittings: Brass UNI EN 12164 – CW614N
- Circulator: Cast Iron
|
REF. |
DESCRIPTION |
Ø |
|
1 |
Cold Water Inlet |
1” M |
|
2 |
Hot Water Outlet |
1” M |
|
3 |
Recirculation provision |
1” M |
|
4 |
Heating System Supply |
1” M |
|
5 |
Heating System Return |
1” M |
|
REF. FW |
FW 40 |
FW 40 PLUS |
|
Packaging L x B x H (mm) |
725 x 420 x 280 | |
|
Packaging weight (kg) |
23 |
24 |
|
REF. CS80 |
1 DN25 |
2 DN25 |
3 DN25 |
|
A |
225 |
385 |
545 |
|
Packaging L x B x H (mm) |
290 x 240 x 150 |
450 x 240 x 150 |
610 x 240 x 150 |
|
Packaging weight (kg) |
3.00 |
4.60 |
6.30 |
|
REF. CS80 |
4 DN25 |
5 DN25 |
1+1 DN25 |
2+2 DN25 |
|
A |
705 |
865 |
225 |
385 |
|
Packaging L x B x H (mm) |
930 x 240 x 160 |
930 x 240 x 160 |
290 x 240 x 150 |
450 x 240 x 150 |
|
Packaging weight (kg) |
8.30 |
9.90 |
3.30 |
5.40 |
Listino prodotto
|
DESCRIPTION |
CODE |
|
FW 40 – ELETTRONIC |
360102 |
|
FW 40 PLUS – ELETTRONIC |
360103 |
Accessories List
|
REF. |
DESCRIPTION |
CODE |
|
1 |
CIRCULATION Kit FW40** |
360154 |
|
|
MIXER VALVE KIT FW40*** |
360155 |
|
|
STORAGE Stratification Valve Kit FW40*** |
360156 |
|
|
STORAGE Stratification Kit – No Valve |
360157 |
|
|
CIRCULATION KIT WITH SUPPLY SENSOR (1 PC) |
360163 |
|
|
STORAGE Sensor Kit |
360165 |
|
|
Relay Exchange Kit |
360166 |
* Pump with built-in clock.
** Pump without clock, timing managed by the producer’s controller.
*** Kit to be installed on the system piping.
MIXER VALVE KIT FW40
Thermostatic mixing valve kit allows upstream temperature regulation in FW instantaneous water heaters. The system improves in accuracy for comfort in primary high temperature conditions.
Packaging composed of:
- Mixer Valve.
STORAGE STRATIFICATION VALVE KIT FW40
The storage stratification kit allows directing the return flow from the producer to the lower part or mid-section of the accumulator. By comparing various temperatures, it promotes the stratification phenomenon inside the thermal accumulator, maximizing the efficiency of the entire heating system.
Packaging composed of:
- Mixer Valve;
- Temperature sensor S5;
- Temperature sensor S6.
|
REF. |
FW40 |
FW40 – PLUS |
|
Nominal flow rate primary storage [m3/h] |
2,4 |
3 |
|
Nominal flow rate DHW [L/min] |
40 |
40 |
|
Residual hydraulic head primary* [kPa] |
12 |
22 |
|
Minimum DHW flow rate [L/min] |
2 |
2 |
|
DHW production (T1 = 55°C- ∆T2=10÷45*C) [L/min] |
32 |
44 |
|
Heat exchange power (T1 = 55°C- ∆T2=10÷45*C) [kW] |
78 |
107 |
|
DHW production (T1 = 60°C- ∆T2=10÷45*C) [L/min] |
39 |
53 |
|
Heat exchange power (T1 = 60°C- ∆T2=10÷45*C) [kW] |
95 |
130 |
|
DHW production (T1 = 65°C- ∆T2=10÷45*C) [L/min] |
45 |
60 |
|
Heat exchange power (T1 = 65°C- ∆T2=10÷45*C) [kW] |
110 |
146 |
|
Secondary DHW circuit pressure drop** [kPa] |
40 |
20 |
|
Max. ass. power [W] |
80 |
80 |
|
Primary circulator [-] |
Wilo PARA |
|
|
Size of the primary circulator |
15/8 |
15/8 |
|
Number of primary circulators |
1 |
1 |
|
Power supply [V] |
230 V AC 50/60 Hz |
|
|
Maximum operating temperature [°C] |
90 °C |
|
|
Maximum pressure in the primary circuit |
10 bar |
|
|
Maximum pressure in the secondary circuit |
10 bar |
|
|
Degree of protection [-] |
IP 40 |
|
|
Diameter and type of hydraulic connections [-] |
G 1” ISO 228/2 |
G 1” ISO 228/3 |
|
Dimensions (b x h x p) [mm] |
395x590x225 |
395x590x225 |
|
Packaging dimensions (b x h x p) [mm] |
420x726x280 |
420x726x280 |
|
Empty weight [kg] |
21 |
19 |
|
REF. |
FW40 |
|
Nominal flow rate primary storage [m3/h] |
2,4 |
|
Nominal flow rate DHW [L/min] |
40 |
|
Residual hydraulic head primary* [kPa] |
12 |
|
Minimum DHW flow rate [L/min] |
2 |
|
DHW production (T1 = 55°C- ∆T2=10÷45*C) [L/min] |
32 |
|
Heat exchange power (T1 = 55°C- ∆T2=10÷45*C) [kW] |
78 |
|
DHW production (T1 = 60°C- ∆T2=10÷45*C) [L/min] |
39 |
|
Heat exchange power (T1 = 60°C- ∆T2=10÷45*C) [kW] |
95 |
|
DHW production (T1 = 65°C- ∆T2=10÷45*C) [L/min] |
45 |
|
Heat exchange power (T1 = 65°C- ∆T2=10÷45*C) [kW] |
110 |
|
Secondary DHW circuit pressure drop** [kPa] |
40 |
|
Max. ass. power [W] |
80 |
|
Primary circulator [-] |
Wilo PARA |
|
Size of the primary circulator |
15/8 |
|
Number of primary circulators |
1 |
|
Power supply [V] |
230 V AC 50/60 Hz |
|
Maximum operating temperature [°C] |
90 °C |
|
Maximum pressure in the primary circuit |
10 bar |
|
Maximum pressure in the secondary circuit |
10 bar |
|
Degree of protection [-] |
IP 40 |
|
Diameter and type of hydraulic connections [-] |
G 1” ISO 228/2 |
|
Dimensions (b x h x p) [mm] |
395x590x225 |
|
Packaging dimensions (b x h x p) [mm] |
420x726x280 |
|
Empty weight [kg] |
21 |
|
REF. |
FW40 – PLUS |
|
Nominal flow rate primary storage [m3/h] |
3 |
|
Nominal flow rate DHW [L/min] |
40 |
|
Residual hydraulic head primary* [kPa] |
22 |
|
Minimum DHW flow rate [L/min] |
2 |
|
DHW production (T1 = 55°C- ∆T2=10÷45*C) [L/min] |
44 |
|
Heat exchange power (T1 = 55°C- ∆T2=10÷45*C) [kW] |
107 |
|
DHW production (T1 = 60°C- ∆T2=10÷45*C) [L/min] |
53 |
|
Heat exchange power (T1 = 60°C- ∆T2=10÷45*C) [kW] |
130 |
|
DHW production (T1 = 65°C- ∆T2=10÷45*C) [L/min] |
60 |
|
Heat exchange power (T1 = 65°C- ∆T2=10÷45*C) [kW] |
146 |
|
Secondary DHW circuit pressure drop** [kPa] |
20 |
|
Max. ass. power [W] |
80 |
|
Primary circulator [-] |
Wilo PARA |
|
Size of the primary circulator |
15/8 |
|
Number of primary circulators |
1 |
|
Power supply [V] |
230 V AC 50/60 Hz |
|
Maximum operating temperature [°C] |
90 °C |
|
Maximum pressure in the primary circuit |
10 bar |
|
Maximum pressure in the secondary circuit |
10 bar |
|
Degree of protection [-] |
IP 40 |
|
Diameter and type of hydraulic connections [-] |
G 1” ISO 228/3 |
|
Dimensions (b x h x p) [mm] |
395x590x225 |
|
Packaging dimensions (b x h x p) [mm] |
420x726x280 |
|
Empty weight [kg] |
19 |
Installation example serves the purpose of illustrating potential installations of FW20T Water Heaters. Please refer to your Engineer for actual installation design. G3 cannot be held liable in the event of adverse consequences which may result from installations designed according to below example.